datacenter placed in Madrid, Spain assures a few excellent accident control measures and an excellent Internet connection.
Interxion is the European provider leader in neutral data centers for the accommodation of teams and managed services. In Madrid are provided with the technologically more advanced
DataCenter of Spain and with an important critical mass of clients of different segments and industries.
Interxion is the operator of telecommunications and Internet leader in Europe. With an infrastructure 100 % of optical, completely proper fibre, in 32 European cities of 13 countries.
The model of initial business was based on the independence of the operators, to obtain multiple network providers, including the principal operators and
ISPs that offer direct access to the networks.
Interxion lodges 9 of the principal European neutral points:
BNIX (Belgium),
COPIX (Denmark),
DE-CIX (Germany),
LINX (United Kingdom),
MAD-IX (Spain),
NL-IX (The Netherlands),
SFINX (France),
SWISSIX (Switzerland) and VIX (Austria).
Interxion counts with more than 33.000 m ² cash of technical space in 20 operative facilities in the principal economic centers of 11 countries.

Germany, Dusseldorf
Germany,
Frankfurt
Austria, Vienna
Belgium, Brussels
Denmark, Copenhagen
Spain, Madrid
France, Paris
Holland,
Ámsterdam
Holland,
Hilversum
Ireland, Dublin
The United Kingdom, London
Sweden, Stockholm
Switzerland, Zurick

The team of professionals in Madrid already has pleasure in being able to give services to more than 60 companies of telecommunications and a fan of companies of several non-technological sectors.
Interxion invested 12 million Euros in the
DataCenter in Madrid most advanced of his sector in Spain.
The servants are located in closets
Rack of 19 ". Every closet
rack has systems of later ventilation, feeding and
SAIs (Systems of Uninterrupted Feeding) independent.
Electrical supply 
The data center has two electrical assaults independent from 15
MVA proceeding from two different origins. Before coming to the teams, the energy always happens for the
UPS infrastructure to assure a clean, leaked and uninterrupted feeding.
Before any incidence of the company of electricity, the electrical supply remains guaranteed by a system of uninterrupted feeding formed by the batteries of the
UPS with a support of the generating groups
back-Up diesel. Contracts of high availability have been signed for the diesel supply within 8 hours. Generators
Caterpillar (n+1) of
back-up diesel with fuel storage to guarantee the continuous supply 24 hours to maximum load.
Air conditioning and environmental control panel
Automatic balanced and redundant system (n+1) of precision air conditioning. The temperature tolerances are of 22ºC ± 2ºC (adaptably). The refreshed air is pumped under the elevation of the soil, for bombs redundant and it extracted by the roof across the air extractors. The air conditioning units
estánn equipped of:
humidificador, ventilation, microprocessor of temperature and control of moisture, sensor of liquid, remote control, manometric pressure and filters.
The high technical Soil allows a vertical clearance on the 29 cm soil. He supports up to 1.500 Kg / m ² of load with the columns of support connected to ground in all his extension and offers antistatic characteristics.
Systems of Protection and Extinction of Fires 
Prevention and Detection of Fires
The Data center is provided with detection systems for sensibility and systems of suppression of fires based on inert gas like the first defense line against the fire. The Rooms of the building are formed in turn by resistance walls to the fire (RF60). The detection system is based, on the one hand, on the optical detection devices by laser, and on the other hand, on an Alarm of Detection of Instantaneous Smokes
(VESDA) to detect particles in the air or other changes in the ambience of the facilities. In case there was a source of excessive heat, this system allows to the Center of Control to be informed immediately about the presence of smoke and to adopt the suitable measurements. He gets ready of a direct line with the Fire department in case of emergency.
Suppression of Fires 
They have installed to themselves systems of suppression of fires by means of Gas in all his facilities. The type of secondhand Gas is an inert gas
(INERGEN), based on the national regulations according to the place of the building. All the facilities are equipped with fire extinguishers, as the national regulations order.
Safety control of access and alertness
The systems of safety, control of access and alertness continue the most strict standards. The building is provided with the following accident control measures:

1. Observers' presence in the building 24 hours a day, 7 days a week.
2. Control of Accesses 24 hours a day, 7 days a week.
3. Identification and record of all the earnings to the building.
4. Doors use human sluices and cabins of restriction of accesses.
5. Alone authorized personnel and registered clients have access to the authorized areas.
6. Norms and safety Procedures and performance for the whole personnel and visits of the building.
7. The safety areas use specific alarms and accesses with codified cards.
8. Monitoring and visual pursuit of all the facilities by means of
CCTV (closed Circuits of Television) and web - cams.
Network and connectivity
The optical fibre comes from 2 different and independent access points to the building. The cables salvers guide the fibre from the above mentioned points of entry to the building up to the
BFP (Flexible Point of the Building), which are those points in which the exterior wiring transforms in wiring for internal use in the building.
The System of Structured Wiring assures the ideal management and improves of the connectivity in the Data center. This type of installation (structured wiring), it facilitates and allows the traffic between networks of a rapid and easy way.
In this moment more than 25 of the principal operators of national and international telecommunications exchange traffic and offer his services in the Data center.
It will obtain accesses to very high speed from any part of the world, be already his potential traffic proceeding from Spain, Europe, the United States, South America or any other country of the world.